READ AND KEEP THIS MANUAL FOR REFERENCE
45793A
Printed in Canada 14-04-2015
Installation and Operation Manual
CW2500
Insert (CB00019 model)
US ENVIRONMENTAL PROTECTION
AGENCY PHASE II CERTIFIED WOOD
INSERT
Safety tested according to ULC S628
and UL 1482 Standards
by an accredited laboratory
www.century-heating.com
Stove Builder International Inc.
250, rue de Copenhague, St-Augustin-de-Desmaures
(Quebec) Canada G3A 2H3
Tel: (418) 878-3040 Fax: (418) 878-3001
This manual is available for free download on the manufacturer’s web site. It is a
copyrighted document. Re-sale is strictly prohibited. The manufacturer may update this
manual from time to time and cannot be responsible for problems, injuries, or damages
arising out of the use of information contained in any manual obtained from unauthorized
sources.
Seitenansicht 0
1 2 3 4 5 6 ... 59 60

Inhaltsverzeichnis

Seite 1 - Insert (CB00019 model)

READ AND KEEP THIS MANUAL FOR REFERENCE 45793A Printed in Canada 14-04-2015 Installation and Operation Manual CW2500 Insert (CB00019 model) US EN

Seite 2

CW2500 Insert Installation and Operation Manual 10 2.3 The Benefits of Low Emissions and High Efficiency The low smoke emissions produced by the sp

Seite 3

CW2500 Insert Installation and Operation Manual 11 3 Fuel 3.1 Materials That Should Not be Burned • GARBAGE OF ANY KIND, • COAL OR CHARCOAL, •

Seite 4

CW2500 Insert Installation and Operation Manual 12 3.2.3 Log Length Logs should be cut at least 1” (25 mm) shorter than the firebox so they fit in e

Seite 5

CW2500 Insert Installation and Operation Manual 13 3.2.5 How to Dry Firewood Firewood that is not dry enough to burn is the cause of most complaint

Seite 6 - 1 Safety Information

CW2500 Insert Installation and Operation Manual 14 3.2.6 Judging Firewood Moisture Content You can find out if some firewood is dry enough to burn

Seite 7 - 2 General Information

CW2500 Insert Installation and Operation Manual 15 4 Operating Your Insert 4.1 Your First Fires Two things will happen as you burn your first few f

Seite 8

CW2500 Insert Installation and Operation Manual 16 4.2.2 The Top Down Fire The top down fire starting method solves two problems with the conventio

Seite 9

CW2500 Insert Installation and Operation Manual 17 Wood burns best in cycles. A cycle starts when a new load of wood is ignited by hot coals and end

Seite 10

CW2500 Insert Installation and Operation Manual 18 4.3.4 Firing Each New Load Hot Place the new load of wood on and behind the charcoal, and not to

Seite 11

CW2500 Insert Installation and Operation Manual 19 4.4 Blower Operation Allow the insert to reach operating temperature (approximately one hour), be

Seite 12

CW2500 Insert Installation and Operation Manual 2 THANK YOU FOR CHOOSING THIS CENTURY WOOD INSERT As one of North America’s largest and most respect

Seite 13

CW2500 Insert Installation and Operation Manual 20 You will need to be cautious when building fires like this because if the air is turned down too

Seite 14 - 3.3 Manufactured Logs

CW2500 Insert Installation and Operation Manual 21 5 Maintaining Your Wood Heating System 5.1 Insert Maintenance Your new insert will give many yea

Seite 15 - 4 Operating Your Insert

CW2500 Insert Installation and Operation Manual 22 5.1.3 Replacing the Door Gasket It is important to maintain the gasket in good condition. After

Seite 16 - 4.3 Maintaining Wood Fires

CW2500 Insert Installation and Operation Manual 23 Do not abuse the glass door by striking or slamming shut. Do not use the insert if the glass is

Seite 17

CW2500 Insert Installation and Operation Manual 24 It is recommended to clean thoroughly the chimney system at the end of every heating season. Duri

Seite 18

CW2500 Insert Installation and Operation Manual 25 PART B - INSTALLATION 6 Pre-Installation Masonry fireplace requirements The masonry fireplace mu

Seite 19 - 4.4 Blower Operation

CW2500 Insert Installation and Operation Manual 26 3. CHIMNEY CAPS: Mesh type chimney caps must have provision for regular cleaning, or the mesh sho

Seite 20

CW2500 Insert Installation and Operation Manual 27 7 Safety Information 7.1 Summary of Installation Cautions and Warnings • THE INFORMATION GIVEN O

Seite 21 - 5.1 Insert Maintenance

CW2500 Insert Installation and Operation Manual 28 8 Clearances to Combustible Material The clearances shown in this section have been determined b

Seite 22

CW2500 Insert Installation and Operation Manual 29 SHELF POSITIONING MAXIMUM SHELF DIMENSION (X) SHELF POSITION(I) 6" / 152 mm 13.5" / 34

Seite 23

CW2500 Insert Installation and Operation Manual 3 Table of content PART A - OPERATION AND MAINTENANCE ... 61 Safety In

Seite 24

CW2500 Insert Installation and Operation Manual 30 Non-combustible floor protection of at least 3" (76 mm) in depth must be installed in front

Seite 25 - PART B - INSTALLATION

CW2500 Insert Installation and Operation Manual 31 There are two ways to calculate the R factor of the floor protection. First, by adding the R-valu

Seite 26

CW2500 Insert Installation and Operation Manual 32 Data for Floor Protection Calculation level with the hearth extension of the masonry fireplace

Seite 27 - 7 Safety Information

CW2500 Insert Installation and Operation Manual 33 Thermal Characteristics of Common Floor Protection Materials* MATERIAL CONDUCTIVITY (k) PER INCH

Seite 28

CW2500 Insert Installation and Operation Manual 34 Data for Floor Protection Calculation MAXIMUM EXTENDED A B (Note 1) C D E AIR JACKET INCHES Di

Seite 29 - SHELF POSITIONING

CW2500 Insert Installation and Operation Manual 35 8.5 Minimum Masonry Opening, Clearances to Combustibles, and Floor Protector

Seite 30

CW2500 Insert Installation and Operation Manual 36 CLEARANCES F 28’’ (711 mm) G 9’’ (229 mm) H 13.5’’ (343 mm) I 13.5’’ (343 mm)* O 4’’ (102 mm)

Seite 31

CW2500 Insert Installation and Operation Manual 37 8.5.1 Reducing Wall and Ceiling Clearances Safely Existing clearances to combustible materials a

Seite 32

CW2500 Insert Installation and Operation Manual 38 Clearances for wall and ceiling shield construction

Seite 33

CW2500 Insert Installation and Operation Manual 39 CLEARANCES 62 3/8 in (1584 mm) Distance between top of insert and ceiling 20 in (500 mm) Shie

Seite 34

CW2500 Insert Installation and Operation Manual 4 5 Maintaining Your Wood Heating System ... 215.1 Insert Maintenance

Seite 35 - Protector

CW2500 Insert Installation and Operation Manual 40 Clearances for top surround, side surround and shelf shield construction

Seite 36

CW2500 Insert Installation and Operation Manual 41 CLEARANCES 62 3/8 in (1584 mm) Distance between top of insert and combustible shelf and combusti

Seite 37

CW2500 Insert Installation and Operation Manual 42

Seite 38

CW2500 Insert Installation and Operation Manual 43 The shield must be flush with the front of the shelf, the combustible top surround and the combu

Seite 39

CW2500 Insert Installation and Operation Manual 44 8.5.3 Table of Clearance Reduction Percentages With Regards To the Type of Shield Type of shield

Seite 40

CW2500 Insert Installation and Operation Manual 45 9 The Venting System 9.1 General The venting system, made up of the chimney and the liner insid

Seite 41

CW2500 Insert Installation and Operation Manual 46 9.3 Suitable Chimneys Your wood insert will provide optimum efficiency and performance when conne

Seite 42

CW2500 Insert Installation and Operation Manual 47 ATTENTION INSTALLER: When positioning the unit in a fireplace opening prior to the flue install

Seite 43

CW2500 Insert Installation and Operation Manual 48 9.5 Chimney liner installation 1) Using a power driver with a Robertson end, secure the elbow (

Seite 44

CW2500 Insert Installation and Operation Manual 49 9.6 Minimum Chimney Height The top of the chimney should be tall enough to be above the air tur

Seite 45 - 9 The Venting System

CW2500 Insert Installation and Operation Manual 5 9.8 Supply of Combustion Air ...

Seite 46 - 9.4 Liner installation

CW2500 Insert Installation and Operation Manual 50 There are two reasons why the chimney in the house at right will cold backdraft when it is cold o

Seite 47

CW2500 Insert Installation and Operation Manual 51 Appendix 1: Optional Faceplate and Decorative Trims Installation Note: The illustrations may var

Seite 48

CW2500 Insert Installation and Operation Manual 52 Insert the superimposed brackets (G) and (H) with the screws (F) in the groove of each decorativ

Seite 49 - 9.6 Minimum Chimney

CW2500 Insert Installation and Operation Manual 53 Center the insert into the fireplace opening. Adjust its height using the leveling bolts on each

Seite 50

CW2500 Insert Installation and Operation Manual 54 Appendix 2: Installation of Secondary Air Tubes and Baffle 1. Starting with the rear tube, lean

Seite 51 - Installation

CW2500 Insert Installation and Operation Manual 55 3. Repeat steps 1 and 2 for the two tubes in the back then install the baffle before installing

Seite 52

CW2500 Insert Installation and Operation Manual 56 Appendix 3: Removal instructions For the purpose of inspecting the insert itself or the fireplac

Seite 53

CW2500 Insert Installation and Operation Manual 57 Appendix 4: Exploded Diagram and Parts List

Seite 54

CW2500 Insert Installation and Operation Manual 58 IMPORTANT: THIS IS DATED INFORMATION. When requesting service or replacement parts for your stove

Seite 55 - Model Type of tube

CW2500 Insert Installation and Operation Manual 59 # Item Description Qty 36 PL66810 BAFFLE SUPPORT 2 37 30029 CUTTING THREAD SCREW 10-24 TYP

Seite 56

CW2500 Insert Installation and Operation Manual 6 PART A - OPERATION AND MAINTENANCE Please see Part B for installation instructions. 1 Safety Infor

Seite 57

CW2500 Insert Installation and Operation Manual 60 CENTURY LIMITED LIFETIME WARRANTY. The warranty of the manufacturer extends only to the original

Seite 58

CW2500 Insert Installation and Operation Manual 7 2 General Information 2.1 CB2500 Specifications Fuel Type Cordwood Test Standards (safety) UL

Seite 59

CW2500 Insert Installation and Operation Manual 8

Seite 60

CW2500 Insert Installation and Operation Manual 9 2.2 Zone Heating and How to Make it Work for You Your new CB2500 wood insert is a space heater